CFNNR - ARDROX 7050-W TEMPORARY COATING REMOVER

  • MSDS: CFNNR
  • Manufacturer: BRENT AMERICA INC
  • Product Name: ARDROX 7050-W TEMPORARY COATING REMOVER
  • National Stock Number: 6810-00N014760
Product Identification

Product ID:ARDROX 7050-W TEMPORARY COATING REMOVER
MSDS Date:12/12/1994
FSC:6810
NIIN:00N014760
MSDS Number: CFNNR

Responsible Party
BRENT AMERICA INC
16961 KNOTT AVE
LA MIRADA, CA 90638
US

Emergency Phone: 714-739-2821;800-424-9300(CHEMTREC)

Info Phone: 714-739-2821

Cage: GO447

Contractor
BRENT AMERICA, INC.
LA MIRADA, CA 90638-6015 US

Telephone: 714-739-2821

Cage: 23373

Ingredients

NOT IN USE. PROTECT CNTNRS FROM PHYSICAL DAMAGE.

RTECS: 9999999ZZ


WELD OR DRILL ON OR NEAR THIS CONTAINER. GROUND ALL

RTECS: 9999999ZZ


EMERGENCY AND OTHER CNDTNS WHERE EXPOSURE

RTECS: 9999999ZZ


POSITIVE-PRESSURE, SELF-CONTAINED BREATHING

RTECS: 9999999ZZ


NECESSARY FOR SOME OPERATIONS.

RTECS: 9999999ZZ


ETHANOL, 2-(2-AMINOETHOXY)-; (DIGLYCOLAMINE)

CAS: 929-06-6

RTECS: KJ6125000

Fraction By Weight: 5-10%

OSHA PEL N/K

ACGIH TLV: N/K


61. VAPOR PRESSURE OF

RTECS: 9999999VO

OSHA PEL N/K

ACGIH TLV: N/K


WATER. DO NOT ATTEMPT TO GIVE FLUIDS TO UNCON

RTECS: 9999999ZZ


BASED ON JUDGEMENT OF PHYSICIAN IN RESPONSE TO

RTECS: 9999999ZZ


COMBUST ABSORB INORG MATL. PVNT RUNOFF FROM

RTECS: 9999999ZZ


TRANSFER CONTAMD ABSORBENT TO A DOT-APPROVED

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: BRTHG OF MISTS IS
IRRITATING TO UPPER RESP TRACT. SKIN CONT: FREQUENT/PRLNGD CONT MAY
BE MODERATELY IRRITATING. EFTS MAY BE DELAYED. SKIN ABSORP:
COMPONENTS ARE UNLIKELY TO BE ABSORBED T HRU SKIN IN HARMFUL CONCS.
EYE CONT: OVEREXP WILL CAUSE EXTREME BURNS THAT MAY RSLT IN PERM
DMG TO EYE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: & EVEN BLNDNESS. INGEST: CAN CAUSE
IRRIT OF STOM & INTESTINES (GI TRACT). TARGET ORGANS, OTHER THAN
THOSE IMPLIED BY ROUTES OF ENTRY (I.E., BREATHED, INCL RESP TRACT &
LUNGS) ARE CAPITALIZED . THIS PROD CONTAINS CHEM(S) KNOWN TO STATE
OF CALIFORNIA TO CAUSE CANCER/REPROD TOX. THESE ARE TRACE AMTS
(SUPDAT)
Medical Cond Aggravated by Exposure:PERSONS WITH PRE-EXISTING SKIN
CONDITIONS MAY BE SUSCEPTIBLE TO THE EFFECTS OF A COMPONENT(S) OF
THIS PRODUCT.

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR @ ONCE. IF NOT BRTHG, GIVE
MOUTH-TO-MOUTH RESUSCITATION. IF BRTHG IS DFCLT, GET IMMED MED
ATTN. KEEP VICTIM WARM & AT REST. SKIN:WASH IMMED W/LOTS OF SOAP &
WATER. IF CLOTHES & SHOES ARE CONTAMD, REMOVE & WASH BEFORE REUSE.
GET MED ATTN IF ILL EFT/IRRIT DEVELOPS. EYES:WASH IMMED W/RUNNING
WATER FOR @ LST 15 MINS. USE FINGERS TO ASSURE EYELIDS ARE
SEPARATED & THAT (SUPDAT)

Fire Fighting

Flash Point Method:PMCC
Flash Point:>200F,>93C
Extinguishing Media:DRY CHEMICAL. ALCOHOL RESISTANT FOAM. CO*2. WATER
SPRAY.
Fire Fighting Procedures:NIOSH APPRVD SCBA & FULL PROT EQUIP . USE
WATER TO KEEP FIRE-EXPOSED CNTNRS COOL & TO FLUSH SPILLS AWAY FROM
FIRE. IN CASE OF LG FIRES ALSO COOL (SUPDAT)
Unusual Fire/Explosion Hazard:NONE ANTICIPATED UNDER CONDITIONS OF
NORMAL USE.

Accidental Release

Spill Release Procedures:CAUTION:USE APPROP PROT & SFTY EQUIP. SEE
SECTION 8 OF MSDS FOR HNDLG PRECAUTIONS. SM SPILL:MOP UP/SOAK UP
W/NON-COMBUST ABSORB INORG MATL. TRANSFER TO DOT-APPRVD CNTNR. LG
SPILL:EVAC SPILL AREA OF UN PROTECTED PERS. CONTAIN BY DIKING
W/NON- (ING 5)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:TRAIN ALL EMPLOYEES ON ALL SPEC HNDLG
PROCEDURES IN THIS SECTION BEFORE THEY WORK W/THIS PROD. EXERCISE
REASONABLE CARE & CAUTION.
Other Precautions:PERS SHOULD AVOID BRTHG VAPS &/OR MISTS & GETTING
PROD IN EYES/ON SKIN. KEEP CNTNRS COOL, DRY, & AWAY FROM SOURCES OF
IGNIT. DO NOT STORE PROD IN DIRECT SUNLIGHT, HIGH TEMP/BELOW
FREEZING AREAS. KEEP PROD CNTNR TIGHTLY CLSD WHEN (ING 7)

Exposure Controls

Respiratory Protection:ATMOSPHERIC LEVELS SHOULD BE MAINTAINED BELOW
EXPOSURE GUIDELINES. WHEN RESP PROT IS REQD FOR CERTAIN OPERATIONS,
USE NIOSH APPRVD FILTER TYPE RESP USED I/A/W REQUIREMENTS OF 29 CFR
1910.134. IN CONFI NED/POORLY VENTILATED AREAS/FOR (ING 9)
Ventilation:CONTROL AIRBONRE CONCS BELOW EXPOSURE GUIDELINES W/MECH
VENT, IF NEC. LOCAL EXPLO-PROOF EXHAUST VENT MAY BE (ING 11)
Protective Gloves:IMPERMEABLE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
PROT CLTHG. BOOTS, APRON/FULL-BODY SUIT.
Work Hygienic Practices:DO NOT CONSUME FOOD, DRINK/TOBACCO IN AREAS
WHERE THEY MAY BECOME CONTAMD W/THIS MATL. WASH THOROUGHLY AFTER
USING.
Supplemental Safety and Health
FIRE FIGHT PROC:SURROUNDING EQUIPMENT & STRUCTURES W/WATER. EFTS OF
OVEREXP:FOUND IN NORMAL TECHNICAL GRADE INDUST MATLS & ARE NOT
DELIBERATELY ADDED TO PROD. FIRST AID PROC:EYE IS BEING WASHED.
LIFT LOWER & UPPER LID OCCASNLY. GET IMMED MED ATTN. INGEST:DO NOT
INDUCE VOMIT. IF VICTIM IS CONSCIOUS, GIVE LG AMTS (ING 3)

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:32.0F,0.0C
Vapor Pres:17
Vapor Density:>1.0
Spec Gravity:1.013
pH:11.1
Evaporation Rate & Reference:<1.0 (BUAC =1)
Solubility in Water:COMPLETE
Appearance and Odor:VISCOUS, GREEN LIQUD. NO ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS. ACIDS, ACID FUMES.
Stability Condition to Avoid:STABLE UNDER NORMAL STORAGE CONDITIONS.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE, &
NITROUS OXIDES MAY BE RELEASED IF HEATED TO DECOMPOSITION.

Disposal

Waste Disposal Methods:CONSULT APPROP FED, STATE & LOCAL REGULATORY
AGENCIES TO ASCERTAIN PROPER DISP PROCEDURES. NOTE:COMPLY W/ALL
APPLIC GOVT REGS ON SPILL RPTG & HNDLG & DISP OF WASTE. EMPTY
CNTNRS CAN HAVE RESIDUES, GAS ES, & MISTS, & ARE SUBJECT TO PROPER
WASTE DISP.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.